In projects where both a tactile guidance system for the visually impaired are to be installed together with an illuminating guidance system for escape in the event of a fire, a combined solution is recommended. This provides a more aesthetically pleasing solution, by avoiding two systems that run parallel and possibly crosswise. Combined products cost less than using one from each solution. There are also large savings in the planning and in assembly.

Combined knobs are used as part of the danger field in the row of the danger field that is closest to the stairs and possibly in rows where the illuminating guide system is to cross the danger field.

Choose between light or dark tactile colour on the knobs, to harmonize with the rest of the field.

Delivered with one of the market’s strongest adhesives 3M VHB5952 and with a 5-year warranty on adhesive adhesives.

 

Illuminating tactile discs, each

£2.38

Clear

Danger fields are mainly used at the top of stairs where they are to be laid one step away from the outer edge of the stairs.

The depth of the field must be 60 cm and the width must be approx. the same as the stairwell.

INFORMATION:

  • Type: Tactile disc combined with illuminating material for marking the part of the danger area where it may also be marked with illuminating
  • Dimensions:
    • External dimensions: 32 mm diameter / 3.7 mm height incl. glue
    • Internal dimensions with illuminating: 25 mm
  • Material: Nylon composite material reinforced with fibreglass for extra strength
  • Illuminated vinyl material for durability and strong luminance when dark or smoky
  • Environment: The tactile part of the indicator is made of 100% recyclable material
  • Colours: Dark anthracite NCS S7502-B and light grey NCS S2000-N
  • Glue: 3M VHB5952 (see own FDV)
  • Warranty: 5 year warranty on adhesive booklet

See our installation guides and videos. 

Additional information

Colour

Light, Dark

Fitting

  • Watch installation videos
  • First clean the area with ST Naturrens.ST Naturrens. ST ST Naturrens is a natural cleanser and not dangerous to inhale. 
  • Always use mal a template for better efficiency and correct results.
  • Attach the template with tape at each end. Glue the products to the floor directly in the template. The glue is so strong that plugs, which were used before, are now superfluous.
  • Move the template over as you place the products.
  • Step on the indicators for better attachment after they are laid.
  • The indicators can be applied directly after installation, but it should not be washed until after 24 hours so that the adhesive has enough time to cure.
  • Choose the right template under related products.